Pacemakers

Our groundbreaking research has allowed us to develop the world’s smallest dual chamber pacemaker¹ and the world's first AutoMRI technology to automatically adjust pacemaker settings for MRI scans², just a few examples of our commitment to product innovation.

Healthcare Professionals Cardiac Rhythm Management Pacemakers

ENO

One with heart

World’s smallest transvenous pacemaker.1 1.5 T and 3 T full body MR conditional. Empower AF Risk Management.

Features

  • SafeR™* – Minimize ventricular pacing for SND and AVB patients.2,3
  • Sleep Apnea Monitoring – Screen and Monitor for Sleep Apnea.
  • AutoMRI – Making MRI scans easy and safe for pacemaker patients.
  • Dual Sensor – Designed to physiologically modulate heart rhythm by combining accelerometer and minute ventilation sensors.

*SafeR Mode (5% V pacing, 50% A pacing), 60 min-1, 2.5 V, 0.4 ms, 750 Ω, SENSORS ON, EGMs ON.

This product is not available for sale or distribution in the USA. For further information on product availability, please contact your local representative.

ENO DR Micro Port 2018

TEO

Break free

World’s smallest transvenous pacemaker.1 1.5 T and 3 T full body MR conditional. Therapies activated automatically at implant.

Features

  • 12 years of longevity* in 8 cc.
  • AutoMRI – Making MRI scans easy and safe for pacemaker patients.
  • SafeR™ – Minimize ventricular pacing for SND and AV Block patients.2,3
  • Dual Sensor – Designed to physiologically modulate heart rhythm by combining Accelerometer and Minute Ventilation sensors.

*SafeR Mode (5% V pacing, 50% A pacing), 60 min-1, 2.5 V, 0.4 ms, 750 Ω, SENSORS ON, EGMs ON.

This product is not available for sale or distribution in the USA. For further information on product availability, please contact your local representative.

TEO DR Micro Port 2018

OTO

Sense in every cc

World’s smallest transvenous pacemaker.1 1.5 T and 3 T full body MR conditional. Fast and Easy follow-up at a click of a button.

Features

  • 11.7 years longevity* in 8 cc.
  • AutoMRI – Making MRI scans easy and safe for pacemaker patients.
  • AutoImplant Detect – Automatically activates algorithms at implant.

*DDDR Mode (50% A & V pacing), 60 min-1, 2.5 V, 0.4 ms, 750 Ω, SENSOR ON, EGMs ON, DIAGNOSTICS ON.

This product is not available for sale or distribution in the USA. For further information on product availability, please contact your local representative.

OTO DR Micro Port 2018

KORA 250

Minimum Size. Maximum Outcome.

Kora 250 is designed to improve patient outcome while driving efficiency in practice.

Features

  • AutoMRI – Making MRI scans easy and safe for pacemaker patients.
  • SafeR™ – Designed to promote intrinsic conduction in patients who need dual-chamber pacing.
  • Sleep Apnea Monitoring – measures respiration pauses and reduction in respiration.
  • Dual sensors – combines an accelerometer and a minute ventilation sensor to provide rate response closest to sinus rhythm.

This product is not available for sale or distribution in the USA. For further information on product availability, please contact your local representative.

Kora250

KORA 100

Always one step ahead

Kora 100 provides the first MRI mode that automatically detects an MRI magnetic field – another innovative solution in a pacing system known for its small size, longevity, and high performance.

Features

  • AutoMRI – Making MRI scans easy and safe for pacemaker patients.
  • SafeR™ – Designed to promote intrinsic conduction in patients who need dual-chamber pacing.
  • Sleep Apnea Monitoring – Measures respiration pauses and reduction in respiration.
  • Dual sensors – Combines an accelerometer and a minute ventilation sensor to provide rate response closest to sinus rhythm.

This product is not available for sale or distribution in the USA. For further information on product availability, please contact your local representative.

KORA 100

Reply 200

Extending the boundaries in cardiovascular disease management.

Reply 200 automatically screens patients at risk of severe sleep apnea, featuring a suite of algorithms designed to prevent serious cardiovascular comorbidities.

Features

  • 12 years longevity* in only 8 cc.
  • SafeR – Dramatically reduces unnecessary RV pacing in all pacemaker patients, including AV block patients.2,3
  • Sleep Apnea Monitoring – Measures respiration pauses and reduction in respiration.
  • Dual Sensor – Designed to physiologically modulate heart rhythm by combining accelerometer and minute ventilation sensors.

*SafeR Mode (5% V pacing, 50% A pacing), 60 min-1, 2.5 V, 0.4 ms, 750 Ω, SENSORS ON, EGMs ON.

This product is not available for sale or distribution in the USA. For further information on product availability, please contact your local representative.

REPLY 200 DR Micro Port 2018

Reply

Natural intelligence

A pacemaker family inspired by nature.

Features

  • SafeR – AV Management proven to be safe and effective for all patients with bradyarrhythmia.2,3
  • 12 years longevity* in only 8 cc. The world’s smallest dual-chamber pacemaker with no compromise on longevity.1
  • Dual sensors – Combines an accelerometer and a minute ventilation sensor to provide rate response closest to sinus rhythm.

*SafeR Mode (5% V pacing, 50% A pacing), 60 min-1, 2.5 V, 0.4 ms, 750 Ω, SENSORS ON, EGMs ON.

This product is not available for sale or distribution in the USA. For further information on product availability, please contact your local representative.

REPLY DR Micro Port 2018

Reply (for US only)

Physiologic performance with uncompromised size and longevity

The world’s smallest dual-chamber pacemaker designed for maximal device longevity. Comprehensive suite of physiologic features available in every Reply DR.1

Features

  • SafeR™ – AV Management proven to be safe and effective for all patients with bradyarrhythmia.2,3
  • Warad – Enables patients to benefit from dual-chamber pacing while preventing inappropriate tracking of atrial tachycardias.
  • Dplus – A dual-chamber pacing algorithm with AV search hysteresis, promotes intrinsic conduction without missing a beat.
  • Twin Trace – Combines an accelerometer and a minute ventilation sensor to provide rate response closest to sinus rhythm.

Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. For indications, contraindications, precautions and warnings for each device, please refer to the product manual.

REPLY DR Micro Port 2018

Esprit

Makes your life easier

The ESPRIT family of pacemakers features a host of dedicated algorithms designed for patient safety as well as Dplus pacing mode which significantly reduces ventricular pacing.

Features

  • Dplus – Automatic AV hysteresis.
  • Lead impedance trend, A&V Autosensing, V Auto threshold.
  • SmartCheck – Automate follow-up tests at the click of a button.

This product is not available for sale or distribution in the USA. For further information on product availability, please contact your local representative.

Esprit
Safer

SafeRTM

SafeR allows for intelligent management of AV conduction, significantly reducing unnecessary RV pacing in all pacemaker patients, including AV block patients.1–8

Discover this therapy
Logo Auto MRI circle blue

AutoMRITM

AutoMRI mode is the world’s first pacemaker technology capable of detecting an MRI field and automatically switching to asynchronous mode.

Discover this therapy
Sam

SAMTM

Proactive management of comorbidities. Early detection, long-term risk reduction. 1–6

Discover this therapy
Parad

PARAD+TM

World's first dual-chamber discrimination algorithm.

Discover this therapy
Dual

Dual SensorTM

Twin trace is designed to physiologically modulate the heart rhythm by combining Accelerometer and Minute Ventilation sensors.

Discover this therapy
Sonr

SonRTM

SonR™ measures real-time LV contractilty1 to optimize AV & VV delays.

Discover this therapy
BTO

BTO™

Active resynchronization

Discover this therapy
Multipoint

Multipoint pacing™

Simultaneous Multipoint Pacing™

Discover this therapy

TECH CORNER

PICTO Paper article

SafeR Pacing Mode

Unnecessary ventricular pacing increases the risk of atrial fibrillation and heart failure hospitalization. SafeR is an algorithm found in the current MicroPort dual chamber models and ensures 99,9% intrinsic conduction, significantly reducing unnecessary pacing. SaferTM reduces unnecessary right ventricular pacing in both Sinus Node Disease patients and unselected AV Block patients.

Click here for full article
PICTO Paper article

Dual Sensor

The goal of rate adaptive pacing is to provide an increase in heart rate via an increase in cardiac pacing in response to metabolic needs: this would include during periods of exercise, but also during disease states and emotional reactions. The dual sensor technology is a combination of an accelerometer and minute ventilation for efficient rate response to chronotropic incompetence. It has been designed to blend information from accelerometer and minute ventilation sensors for a more physiologic rate response.

Click here for full article
PICTO Paper article

Rest Rate

Rest Rate is related to rate adaptive pacing. While rate adaptive pacing increases the pacing rate to address patient demands, the rest rate algorithm uses similar data to slow the pacing rate below the programmed basic rate. In this manner, it can reproduce circadian variations without the constraint of being set by a clock schedule. In addition, rest rate has the added benefits of potentially reducing percent pacing and therefore extending battery life, and may offer patients a more physiological pacing rate.

Click here for full article
PICTO Paper article

Sleep Apnea Monitoring (SAM)

With the Sleep Apnea Monitoring (SAM) function, MicroPort pacemakers provide the physician with automatic screening of pacemaker patients for the risk of severe Sleep Apnea. SAM has been designed to detect, count and report abnormal breathing events during the night. These events are detected using the minute ventilation signal. This allows the calculation of respiratory disturbances over the last six months, representing sleep disordered breathing events at night.

Click here for full article
PICTO Paper article

Window of Atrial Rate Acceleration Detection (WARAD)

The WARAD is designed to monitor the atrial activity in order to discriminate pathological atrial waves (Atrial Fibrillation, Atrial Flutter, Atrial Tachycardias) from sinus P waves. This atrial discriminator uses atrial prematurity to trigger mode switching. Refer also to the Fallback Mode Switch Tech Corner article for more details on the Fallback Mode Switch algorithm.

Click here for full article
PICTO Paper article

Fallback Mode Switch

The FMS function is designed to diagnose atrial arrhythmias and manage their occurrence using the WARAD (Window of Atrial Rate Acceleration Detection): in the event of atrial arrhythmia, FMS switches from DDD®, SafeR® or Dplus® pacing mode to an inhibited dual- chamber pacing mode DDI® to avoid prolonged ventricular pacing at a high rate for the entire duration of the sustained atrial arrhythmia.

Click here for full article
PICTO Paper article

Automatic Implantation Detection

Automaticity at Implantation allows the pacemaker to automatically detect if the device is implanted. It has been designed to provide a secure functioning of the device during implantation without prior or post implantation interrogation.

Click here for full article
PICTO Paper article

Anti-PMT (Pacemaker Mediated Tachycardia) algorithm

The Anti-PMT algorithm is intended to protect the patient from Pacemaker-Mediated Tachycardia (PMT) without reducing the atrial sensing capability of the device.

Click here for full article

MICROPORT® CRM Manuals

http://www.microportmanuals.com/


Availability of select products and their functions vary by country. Please check with your representative for further information.

  1. Competition comparison across transvenous pacing systems made as of August 2020, refer to manufacturers manuals
  2. Stockburger M, et al. Safety and efficiency of ventricular pacing prevention with an AAI-DDD changeover mode in patients with sinus node disease or atrioventricular block: impact on battery longevity-a substudy of the ANSWER trial. Europace 2016;18:739–46.
  3. Stockburger M, et al. Long-term clinical effects of ventricular pacing reduction with a changeover mode to minimize ventricular pacing in general population (ANSWER study). Eur Heart J. 2015;36:151–57.